GE Healthcare · MRSigna2247386185712247384
16 channel switch diag fail channel 13 on multiple input/outputs due to16 channel switch, importantly with RRF chassis s…
16 channel switch diag fail channel 13 on multiple input/outputs due to16 channel switch, importantly with RRF chassis system loopback diags passing. 16 Channel Switch Diagnostics Fail.
Symptom
16 Channel Switch Diagnostics Fail
Error message
2247386 Diagnostic error. The signal's energy level is marginally below the expected value. 2247386 tempmr diagCoord rrfRxFruIso.c 1539 Diagnostic: 16 Channel Switch Iteration: 1 of 1 Action: 1 Task ID: 0x3fa6a60 Time: 18571 Object: APS Test Task Test: '16 Ch Switch Input Osc. AB, Port A' diagnostic error. The signal's energy level is marginally below the expected value. The channels are: 1-8-> 2247384 Diagnostic error. The signal's energy level is severely below the what is expected. See Long Description 2247384 tempmr diagCoord rrfRxFruIso.c 1539 Diagnostic: 16 Channel Switch Iteration: 1 of 1 Action: 1 Task ID: 0x3fa6a60 Time: 18571 Object: APS Test Task Test: '16 Ch Switch Input Osc. AB, Port A' diagnostic error. The signal's energy level is severely below the what is expected. 'Dead' channels are: 1-8-> Extended Error: Sys Cab and UTNS Bypass Diag: Dead channels while running these diags indicate a problem with a board in the receive chain (MUX, UTNS, Rx), or cables between the boards. Sixteen bad channels (or eight bad channels in an eight channel system would indicate a problem with the signal source, or problems other than the three receive chain boards. Eight bad channels
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- SecondOpinion 1.5T Excite HD 16 Channel Switch 5109645 See comments in resolution concept for second opinion requirements before ordering this part
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.