GE Healthcare · MRSigna2252239112143041722612392254030
Fails TPS Reset when booting up to Applications or when Resetting TPS due to Driver Module powered off.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2252239 Startup Timeout was detected on the Master RRF-DIF. Thu May 19 10:38:33 2005 Error: 2252239 Host: pzmrov Process: NSP File: SCP:CanAutoConfig Line: 1393 Startup Timeout was detected on the Master RRF-DIF 2252239 Startup Timeout was detected on the RF NB Amp Interface. Fri Jul 15 11:46:26 2005 2252239 2 lx-mr NSP SCP:CanAutoConfig 2576 Startup Timeout was detected on the RF NB Amp Interface.-> 2252239 Startup Timeout was detected on the Patient Handling Power Supplies. Fri Jul 15 11:46:26 2005 2252239 2 lx-mr NSP SCP:CanAutoConfig 2576 Startup Timeout was detected on the Patient Handling Power Supplies.-> 2252239 Startup Timeout was detected on the Drivers Control Board 2252239 Startup Timeout was detected on the Universal Power Monitor 1. Fri Jul 15 12:26:57 2005 2252239 2 lx-mr NSP SCP:CanAutoConfig 2576 Startup Timeout was detected on the Universal Power Monitor 1.-> 2252239 Startup Timeout was detected on the Universal Power Monitor 2. 1121430417 3 1 Fri Jul 15 12:26:57 2005 2252239 2 lx-mr NSP SCP:CanAutoConfig 2576 Startup Timeout was detected on the Universal Power Monitor 2.-> EN 168 SR 259 2252239 Startup Timeout was detected on the Master Gradient. Mon May 23
Applies to
- Models
- Signa
- Product
- 3.0T Signa HDxT For 3.0T Signa HDxT systems with 15.0 software only. For 3.0T Signa HDxT systems with 15.0 software only.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.