Fails TPS Reset when booting up to Applications or when Resetting TPS due to Driver Module powered off.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2252239 Startup Timeout was detected on the Master RRF-DIF. Thu May 19 10:38:33 2005 Error: 2252239 Host: pzmrov Process: NSP File: SCP:CanAutoConfig Line: 1393 Startup Timeout was detected on the Master RRF-DIF 2252239 Startup Timeout was detected on the RF NB Amp Interface. Fri Jul 15 11:46:26 2005 2252239 2 lx-mr NSP SCP:CanAutoConfig 2576 Startup Timeout was detected on the RF NB Amp Interface.-> 2252239 Startup Timeout was detected on the Patient Handling Power Supplies. Fri Jul 15 11:46:26 2005 2252239 2 lx-mr NSP SCP:CanAutoConfig 2576 Startup Timeout was detected on the Patient Handling Power Supplies.-> 2252239 Startup Timeout was detected on the Drivers Control Board 2252239 Startup Timeout was detected on the Universal Power Monitor 1. Fri Jul 15 12:26:57 2005 2252239 2 lx-mr NSP SCP:CanAutoConfig 2576 Startup Timeout was detected on the Universal Power Monitor 1.-> 2252239 Startup Timeout was detected on the Universal Power Monitor 2. 1121430417 3 1 Fri Jul 15 12:26:57 2005 2252239 2 lx-mr NSP SCP:CanAutoConfig 2576 Startup Timeout was detected on the Universal Power Monitor 2.-> EN 168 SR 259 2252239 Startup Timeout was detected on the Master Gradient. Mon May 23
Applies to
- Models
- Signa
- Product
- 3.0T Signa HDxT For 3.0T Signa HDxT systems with 15.0 software only. For 3.0T Signa HDxT systems with 15.0 software only.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.