GE Healthcare · CTLightSpeedVCT260132766260132503260132488219544
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260132766 List of Digital Interface Boards From the Previous Error Message See LD for full error. This is an advisory message and always has the real message previous to it. Wed Jun 28 09:29:23 2006 Error: 260132766 Host: orp Process:orp_subsys File: IfbError.cxx Line: 368 Wed Jun 28 09:29:22 2006 Host : Das Ermes # : 260132766 Exception Class : Secondary Severity : Sec/Soft File : IfbError.cxx Line# : 368 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 List of Digital Interface Boards From the Previous Error Message Card List: 1,4,7,9,11,13,16,19-21 Error: 260132503 DCB has detected IFB parity error(s) See Long Description for Details Error: 260132503 DCB has detected IFB parity error(s). Wed May14 13:25:30 2008 Error: 260132503 Host: orp Process: orp subsys File: Acquisition.cxx Line: 1675 Wed May14 13:25:30 2008 Host : Das Ermes # : 260132488 Exception Class : Abort Severity : Primary File : Acquisition.cxx Line# : 1675 Function : No System Function Reported Scan Type : Scout Scan: 1306/1 Scan ABORT -- DAS Has Detected An Error. The DCB has detected IFB parity error(s). IFB View: Timeout: 219544 IFB Feedback: 0x400000. View Number: 0
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required