GE Healthcare · CTLightSpeedVCT26011100722567303263626011100311569260111002
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Gantry Control Panel Flashing "ERR". Gantry Control Panel Flashing "ERR"
Error message
Error: 260111007 Communication reestablished to GUIF CAN node ID# 1 (or nodes 2,3,4) See LD for details Wed Apr 4 16:55:13 2007 Error: 260111007 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 1908 Wed Apr 4 16:55:13 2007 Host : Table Gantry Processor Ermes # : 260111007 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 1908 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : None/Unknown Scan: 9106/1/0 Communication reestablished to GUIF CAN node ID# 1. Node part number 2256730. Node serial number 32636. Error: 260111003 GUIF CAN bus error status returned. See LD for Full Error Error: 260111003 GUIF CAN bus error status returned. Fri Jan 21 10:30:39 2005 Error: 260111003 Host: tgp Process: tgp_subsys File: guif_can_mgr.c Line: 490 Fri Jan 21 10:30:38 2005 Host : Table Gantry Processor Ermes # : 260111003 Exception Class : Soft Severity : Sec/Soft File : guif_can_mgr.c Line# : 490 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : Helical Scan: 11569/2/2 GUIF CAN bus error status returned. Error status 0x3. Error: 260111002 GUIF CAN bus error warning See the LD for the full error code Error: 2601110
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required