GE Healthcare · MRDiscovery22688442224666
Error 2268844 due to defective IBC sensor.
Symptom
Unable to scan with IBC temperature faults.
Error message
2268844 Gradient coil IBC inlet temperature is above the fault limit. Current and future scanning will be inhibited, until temperatures are back in range. Temperature Delta: 18 Fault Limit: 4-> 2268844Gradient coil IBC inlet temperature is above the fault limit.Current and future scanning will be inhibited, until temperaturesare back in range.Temperature Delta: %dFault Limit: %d Extended Error: The gradient coil has inner bore coolant (IBC) temperature sensorsthese sensors are on the outside of the gradient coil and are intended tomeasure the temperature of the coolant in the coil. A difference betweenthese readings indicates that the coolant flow is likely blocked in thegradient coil or in the manifold. 2224666 Auto Prescan failed, Gradient coil IBC inlet temperature delta sensor trip See Long Description 2224666 CMR3T psc ../PscMainControl.cc 1375 Exception Class: Unknown Function: Prescan: Host Autoprescan Auto Prescan failed, Gradient coil IBC inlet temperature delta sensor trip
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5426726 IBC Temperature Sensor Replacement Kit 5426726 IBC Temperature Sensor Replacement Kit
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.