GE Healthcare · CTLightSpeedVCT2387801607916071
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Old exam not in database keeps showing up when trying to edit patient data for another current exam. See Long Description. Old exam not in database keeps showing up when trying to edit patient data for any current exams Exam 1886 would also want to be edited when choosing any exam. All queues recon,archive, filming, network, and auto film are empty. Exam 1886 was not in /usr/g/data_management or under Retro Recon.
Error message
Do Not Use - use 238780 - Error: 16079 EPD One non-CT/MR image type found: image skipped Tue Aug 2 13:17:01 2011 Error: 16079 Host: MCGECT01 Process: editPatientData File: Line: 0 EPD One non-CT/MR image type found: image skipped Error: 16071 [EPD] Detected missing images See Long Description for full error Thu Aug 20 18:35:16 2009 Error: 16071 Host: koict Process: editPatientData File: Line: 0 [EPD] Detected missing images
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 11MW4.1 LightSpeed VCT Quatra with Titan configuration supports Sherlock and Halo detectors for GOC6.5 consoles This software is now obsolete, this site should be upgraded to 11HW12.5 software released via FMI 25427 11MW4.1 LightSpeed VCT Quatra with Titan configuration supports Sherlock and Halo detectors for GOC6.5 consoles 11MW4.1 sofware is forward production software there are no plans to FMI it. The 11MW4.1 software Is basically quatra software “LightSpeed VCT Quatra 10MW44.X”. We have a new FMI going out that will cover all of the GOC6 series console that release is call Dose Check 11HW12.4 The only difference between 10MW44.X and 11MW4.1 is that 11MW4.1 is supports Sherlock and Halo detectors for GOC6.5 consoles. 11HW12.4 will be fmi’d to all GOC6 and GOC6.5 the software is called “Quatra Dose Check”
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required