LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260132523 DAS Has Detected An Unexpected Gap In View Triggers. The Cause Is a Momentary Disruption In The Trigger Path. This Typically Occurs Due to Slip-Ring Issues. Thu Oct 5 06:53:14 2006 Error: 260132523 orp orp_subsys Acquisition.cxx 1478 Thu Oct 5 06:53:13 2006 Host : Das Ermes # : 260132523 Exception Class : Abort Severity : Secondary File : Acquisition.cxx Line# : 1478 Function : No System Function Reported Scan Type : Axial Scan: 50190/1/1 The DAS Has Detected An Unexpected Gap In View Triggers. The Cause Is a Momentary Disruption In The Trigger Path. This Typically Occurs Due to Slip-Ring Issues. Error: 260132523 DAS Has Detected An Unexpected Gap In View Triggers. The Cause Is a Momentary Disruption In The Trigger Path. This Typically Occurs Due to Slip-Ring Issues. Thu Oct 5 06:53:14 2006 Error: 260132523 orp orp_subsys Acquisition.cxx 1478 Thu Oct 5 06:53:13 2006 Host : Das Ermes # : 260132523 Exception Class : Abort Severity : Secondary File : Acquisition.cxx Line# : 1478 Function : No System Function Reported Scan Type : Axial Scan: 50190/1/1 The DAS Has Detected An Unexpected Gap In View Triggers. The Cause Is a Momentary Disruption In The Trigger Path. This
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5270886 Small Signal Brush Tip Kit and 5350798 high silver tip kit Replace 2349604 SIGNAL BRUSH TIP COLLECTOR 4 signal brush tips and caps per kit See Long Description for details Refer to attached service note for Important details SN09092411a This full set of Signal Brush Part Number has been divided up to two smaller Part numbers refer to SN09092411a 5270886 Signal brush kit quantity of 4 tips and caps (order 5 to get full set of 20 signal brush tips). 5350798 Red Type1 tip (High silver content) signal brush kit quantity of 4 tips and Caps _______________________________________________________________________________ Part #: 5270886 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Small Signal Brush Tip Kit FRU: Yes Status: Orderable Comments: 4 signal brush tips and caps per kit. Order a quantity of 5 for an entire set of signal brush tips. Kit does not contain type 1 red tip high silver content brush tips. Order part 5350798 for high silver tips. 212007413, Aug-2009 Per ECR 2087298, 212008898, 7/20/09. Part #: 5350798 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Small Signal Type 1 Brush Tip Kit FRU: Yes Status: Orderable Comments: 4 type 1 high silver content signal brush tips and caps per kit. 212007413, Aug-2009 Per ECR 2087298, 212008898, 7/20/09.
- Area
- CT
Full cause & step-by-step resolution