GE Healthcare · CTLightSpeedVCT290012013290012014
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Recon self test failure on boot up. Recon self test failure on boot up
Error message
Error: 290012013 BP error, errno = 5 See long description for full error Thu Nov 15 03:30:38 2007 Error: 290012013 Host: ig3 Process: image_generation File: VRACInterface.cpp Line: 378 BP error, errno = 5 Error: 290012014 Warning: BP start failure See LD for details Mon Nov 5 15:36:50 2007 Error: 290012014 Host: ig3 Process: image generation File: Bp3dVRAC.cpp Line: 201 Warning: BP start failure BP1, BP2, BP3 Projection Memory 0,1.2 Parity Errors found in the IG or VIG messages log See Long Description for complete error and location. BP1, BP2, BP3 Projection Memory 0,1,2 Parity Errors rsh darc > rsh ig1 > cd /var/log > cat messages | grep Error Mar 8 11:28:08 ig1 kernel: vrac: command status error: BP1 Projection Memory 1 Parity Error Mar 8 11:28:08 ig1 kernel: vrac: command status error: BP1 Projection Memory 2 Parity Error In the above example, the errors could be BP1, BP2, or BP3, and Memory 0,1,2
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required