Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT

LightSpeed 1.X - GRE

Symptom

Chattering noises heard inside the PDU and K2 contactor chatters every time it is energized

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 1.X - GRE H1_P_S4 Lightspeed 1.X - GRE Method of visual identification Large square gantry similar in appearance to a CTi gantry. Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-186852P2 A1K2 contactor See long description for details and picture Part #: 46-186852P2 Part Type: GP CONSUMABLES Part Weight: 1.36 LBR Repairable: No Returnable: No Hazardous Material: N Description: RELAY (K2 BACK-UP CONN.) FRU: Yes Status: Orderable Comments: FLS - ALSO AVAILABLE AS 46-186852P2UUSE UP THAT STOCK FIRST! SWITCH ON SIDE OF RELAY= 46-296690P1 A4K2 PF8 TWICE FOR FE ASSIST COMMENTS!!! FOR FE ASSIST PF8 AGAIN!!! FE ASSIST: IN ORDER TO INCREASE REVENUE GLOBAL PARTS HAS CREATED A PROGRAM TO HARVEST PARTS FROM RENEWABLE RESOURCES. THESE PARTS OFFER DIRECT SAVINGS TO THE BUSINESSAND THE FIELD. ORDER THE "U" PARTS WHEN AVAILABLE., IF NO "U" USED PARTS ARE AVAILABLE CARES WILL CHANGE THE ORDER TOA NEW PART. FLS - FE ASSIST MS6588 10/2000 46-186852P2 = AXIAL RELAY ARE YOU ORDERING THE CORRECT PART?? FOR CT PDU THE AXIAL RELAY ASMIS MADE UP OF TWO RELAYS, THE 46-186852P2 & 46-296690P1 P1 RELAY MOUNTED ATOP OF P2. 46-186852P2 = AXIAL LOOP CONTACTOR RELAY. 46-296690P1= AUXILIARY CONTAC T RELAY. SEE CTI FRU MANUAL PAGE 5-5 REVISION 26 AND ABOVE, OLDER REV DO NOT SHOW THE AUX RELAY. DO YOU STILL WHAT TO ORDER THIS PART??
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues