GE Healthcare · CTLightSpeedVCT230017124550000

LightSpeed 2.X (Plus, QX/i) - GRE

Symptom

System fails fastcals with z-slope errors

Error message

Error: 230017124 Read minimum over maximum ratio from ZslopeCal.cfg is 0.550000. See LD for Full Error Error: 230017124 Read minimum over maximum ratio from ZslopeCal.cfg is 0.550000. Tue Dec 27 14:51:03 2005 Error: 230017124 Host: ct01 Process: accs File: zslope.c Line: 1910 Read minimum over maximum ratio from ZslopeCal.cfg is 0.550000.

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 2.X (Plus, QX/i) - GRE always an SDAS 4 slice H2_P_S4 (SDAS4 and H2 gantry) Lightspeed 2.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 3.X and 4.X. Always has an SDAS 4 slice Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2225218 DCB HOUSING ASM for SDAS See LD for details Part #: 2225218 Part Type: GP REPAIRABLES Part Weight: 0.66 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: DCB HOUSING ASM (SDAS) FRU: Yes Status: Orderable ====================== Parts Offered as: Current: 2225218 Harvested: Not Available Exchange: Not Available Comments: FLS - DCB ASM, P/N 2225218 7/31/02- C2R COMPLETED PER M DIGGINS, CHANGE ORDER TO T3202KJ BEFORE SHIPPING. MS12464 CAN'T ORDER DAS ASSY SEE T3202KJ 1/2/02 VEN HAS 20 PC MINIMUM BUY PER PO AND 60 DAY LEAD TIME. MS09121 *** CD & S NOTE **** BEFORE REPLACING THE SDAS DAS CONTROL BOARD (DCB), MEASURE THE +5V ON THE BOARD FROM TP-1 - TP-2. VERIFY THIS IS ABOVE4.8 VOLTS. VOLTAGE LOWER THANTHIS MAY CAUSE INTERMITTENT OPERATIONS. IF THE VOLTAGE ISOK ON THE CONVERTER CARD CHASSCHASSIS, YOU MAY HAVE A CABLE PROBLEM. MS30863 5/31/02 GELS - CSO0111459 FRANCE F-45071720002 /04/01/TS FIBER OPTIC FREQ 50 MHZ / NEEDS DIP BOARD 2275604 OR 2245261 PDB 02/01/21,DCB HOUSING ASM
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.