GE Healthcare · CTLightSpeedVCT260111049
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Gantry Control Panel Flashing "ERR". Gantry Control Panel Flashing "ERR"
Error message
Error: 260111049 Gantry buttons are not effective because drives are not reset after emergency off. See long description for details Error: 260111049 Gantry buttons are not effective because drives are not reset after emergency off. Mon May 16 22:34:09 2011 Error: 260111049 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 1865 Mon May 16 22:34:08 2011 Host : Table Gantry Processor Ermes # : 260111049 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 1865 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : None/Unknown Scan: 0/0/0 Gantry buttons are not effective because drives are not reset after emergency off, or because Gantry UIF communication is not ready. At least, need the following number of UIF devices. 1 Gantry Display(s), 1 Gantry Control(s), 0 Breathing Light(s)
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5310000-3 Right CT Control Panel - White N9 Bezel and Blue LEDs See long description Part #: 5310000-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Right CT Control Panel - White N9 Bezel and Blue LEDs FRU: Yes Status: Orderable Comments: . Per VCT Vision RSPL, 212008898, 1/28/09
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.