Fails TPS Reset when booting up to Applications or when Resetting TPS due to UPM Processor bd.Fails TPS Reset when booti…
Fails TPS Reset when booting up to Applications or when Resetting TPS due to UPM Processor bd.Fails TPS Reset when booting up to Applications or when Resetting TPS.Replace UPM Processor Board 2359518-…
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2252161 WARNING SDO Block Download attempted to an unsupported node. 2252161 ERROR: EM_CAN_SDO_BLK_DLD_NOT_SUPPORTED WARNING: SDO Block Download attempted to an unsupported node. Node ID = %d Index = 0x%x. SubIndex = 0x%x. Possible cause(s): Firmware 2252161 Host: HMR4 Process: NSP File: SCP:NodeData Line: 821 Exception Class: UnknownSeverity: Unknown Function: Peripherals: Communications PSD: UnknownCoil: UnknownScan: -1/-1 WARNING: SDO Block Download attempted to an unsupported node. Node ID = X Index = 0xXXXX. SubIndex = 0xX Possible cause(s): Firmware 2252151 Firmware Detected on Drivers Control Board DSP2 is different from the file Thu Sep 16 13:37:41 2010 2252151 1 HDe_mfg NSP SCP:CanAutoConfig 1917 Exception Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 Firmware Detected on Drivers Control Board DSP2 is different from the file resident on the Host. Flash Downloading Firmware to Board. This is expected to happen during new Software Loads.
Applies to
- Models
- Signa
- Product
- Signa HDxT Apps. For use with HD16.0_VO1 and HD16.0_VO2 version software only. For use with HD16.0_VO1 and HD16.0_VO2 version software only.
- Software
- HD16 Includes HD16.0_VO1 and HD16.0_VO2 version software and applies to 1.5T and 3.0T "Signa HDxT Apps" systems only. Includes HD16.0_VO1 and HD16.0_VO2 version software and applies to 1.5T and 3.0T "Signa HDxT Apps" systems only.
- Component
- 2359518-2 UPM PROCESSOR BOARD.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.