GE Healthcare · MROptima222387800163111946213912228422
Error while loading BAM 2228422 during TPS reset caused by ICN.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2223878 A process has crashed on the VRE (00 30 48 59 F0 64[icn1]). Process dpserver, signal causing the crash 7, time 001631, date: 2007-11-10, UTC 1194621391 2223878 HDe_mfg NSP VREReset.cc 1008 Exception Class: Unknown Function: Recon: Data Acquisition A process has crashed on the VRE (00:30:48:59:F0:64[icn1]). Process: dpserver, signal causing the crash: 7, time: 00:16:31, date: 2007-11-10, UTC: 1194621391. Extended Error: During a TPS Reset the VRE gets scanned for core files that were generated since the last TPS Reset or System Restart. Only one such message is generated even if there is more than once core file. The oldest core file found across all ICNs is listed in this message. 2228422 Error occurred while loading BAM. Please perform a TPS reset. see long description Error: 2228422 Host: dvmr Process: LxMxConsumer File: BamDistribution.cpp Line: 308 Server Name: DP3 Error occurred while loading BAM. Please perform a TPS reset. Contact a service representative if problem persists.
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 5337894 Image Compute Node - DV 16CH GEN 3 5337894 Image Compute Node - DV 16CH GEN 3
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Can Not Boot Applications Software Due To ICN.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- Images failed to reconstruct due to a failed Image Compute Node.