Inductive or Direct Drive Bias fault Due to Hybrid Splitter.Unable to Scan with Inductive or Direct Drive Bias Fault.Rep…
Inductive or Direct Drive Bias fault Due to Hybrid Splitter.Unable to Scan with Inductive or Direct Drive Bias Fault.Replace the 1.5T Body Hybrid Splitter - XQR.Signa HDxT.2252311 DD Driver Fault Dete…
Symptom
Unable to Scan with Inductive or Direct Drive Bias Fault Unable to Scan with Inductive or Direct Drive Bias Fault. Sat Apr 23 10:21:22 2005 Error: 2225526 Host: lx-mr Process: NSP File: HPC_PORT_ID:spi_tr_mon Line: 6100 Inductive or Direct Drive fault, or Body TR switch fault due to impedance mismatch, path short Drive bias fault. Possibly a shorted diode in the driver switches, or a short circuit load.
Error message
2252293 The Driver Module Has Detected a Fault. Wed Apr 21 20:00:24 2004 Error: 2252293 Host: lx-mr Process: NSP File: SCP:DCB Line: 1986 The Driver Module Has Detected a Fault.^A Details of the Fault can be found in other error messages.-> 2252311 DD Driver Fault Detected - Short Circuit. Source of Fault is DD (Direct Drive inside the Body Hybrid Assembly). Error: 2252311 PSD: xxx Coil: xxx Scan: xxx DD Driver Fault Detected - Short Circuit. Source of Fault is DD (Direct Drive inside the Body Hybrid Assembly). Value: xxx mA Limit: xxx mA-
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 5219884 NMR Spare Part Collector For Netcom 1.5 T splitter 5219884 Netcom 1.5T HYBRID SPLITTER, MOUNTING SPACERS, & ISOLATION BOX MOUNTING BRACKETS 5219884 Netcom 1.5T HYBRID SPLITTER, MOUNTING SPACERS, & ISOLATION BOX MOUNTING BRACKETS Check latest service documentation.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.