GE Healthcare · CTLightSpeed260140019

LightSpeed RT16 & RT16 Xtra and Vision

Symptom

Gantry fails to reset properly via the console, but resets ok with gantry re-power. see long description for more detail. Gantry fails to reset properly upon reboot, or via scan hardware reset, the message "scanning hardware reset successful" is returned very quickly, but the Ganty display is blank, and all table/gantry functions are disabled, but if the gantry is repowered via the service switches or at the PDU, the reset works properly, and the system operates normally.

Error message

Error: 260140019 HARD RESET through serial connection failed. see long desription for complete error Sat Oct 24 12:57:29 2009 Error: 260140019 Host: DTHCTGE01 Process: device_control File: device_control_proto.cxx Line: 157 HARD RESET through serial connection failed. some controllers(TGP, ORP, IPC, PROP, PSC) do not response to ping.

Applies to

Models
LightSpeed
Product
LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2404320-2 CONSOLE INTERCOM PRESCRIBED-TILT HUB See Long Description for More ... 2404320-2 CONSOLE INTERCOM PRESCRIBED-TILT HUB Part #: 2404320-2 Part Type: GP CONSUMABLES Part Weight: 0.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: CONSOLE INTERCOM PRESCRIBED-TILT HUB FRU: Yes Status: Orderable Comments: Per ECR 2062448, 212008898, 10/8/08. ** FE ASSIST ** CT/PET Discovery System's must use the P/N 2404320. CT System's must have FMI 25407 or FMI22918 for RT16/Xtra performed prior to installing 2404320-2. Verify Software Configuration before ordering/installing this FRU. To do this, open a Unix Shell and verify one of the following base software versions is installed: ctuser@hostname} swhwinfo -v 07MW11.10_SP2-0-26.Hardware info / 07MW18.4_SP2-0-26.Hardware info / 07BW08.4_SP2-0-26.Hardware info / 08BW17.7 Hardware info / 08BW20.x Hardware info (212001261 10/21/08)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.