Symptom
Cradle will not drive in or out. Cradle will not drive in or out
Error message
Error: 182216 HW/SW error: Motion was prohibited by hardware Limit switches. Hardware Inhibit Switches 0x84dc See long descripton for full sample error message. Fri Dec 21 10:12:18 2007 Error: 182216 Host: ETC Process: Cradle File: cmcStart.c 1.60 7/23/96 Line: 415 Function: PATIENT ANATOMY POSITIONING : Cradle Drive Scan: 28360/2/2 Type: Helical Exception Level: Pri/Soft Time: 10:12:19:245 Log Series: 408 HW/SW error: Motion was prohibited by hardware Limit switches. Hardware Inhibit Switches 0x84dc Current Position 80327 (.01 mm) Dir: 1 (0 = Out 1 = In [Gantry]) Characterization Limits 0 (.01 mm) 170300 (.01 mm) Error: 182105 LAN Watchdog TIMEOUT for uuid 93 (193=OBC; 93=ETC). See LD for error example. Tue Oct 25 22:34:14 2005 182105 3 CT01 STC Master Exc Handler exm_lan_wdog.c No Method 793 Function: No System Function Reported Scan: 161/2/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 22:33:56:310 Log Series: 223 LAN Watchdog TIMEOUT for uuid 93 (193=OBC; 93=ETC). HW/SW Error: Did not receive LAN Watchdog message. Will need a Hardware Reset. Error: 182125 LAN Watchdog TIMEOUT with OBC or ETC (uuid 93, 193) (SW opening abort relay). See LD for full errors Mon Dec
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required