Symptom

Unable to save system state with no errors in the gesyslog. Unable to save system state with no errors in the gesyslog System asks FE to insert the media into the DVD Ram drive in the scsi tower and then hit ENTER. FE follows the directions and then gets a prompt asking him to put an MOD into the drive . OR Message pops up " MOD is a GE DICOM IMAGE ARCHIVE DISK "

Error message

Version Addition failed DVD completed with errors (-1) (Found in sysstate.log) insite@mvhogectrad02 log$ pwd /usr/g/service/log insite@mvhogectrad02 log$ ls -al sys* -rw-rw-rw- 1 ctuser users 65136 Jun 16 06:59 sysReset.timers.log -rw-rw-rw- 1 ctuser users 7000 Jan 5 2010 sysstate.log.20100105_202628 -rw-rw-rw- 1 ctuser users 1589 Jan 20 2010 sysstate.log.20100120_185554 -rw-rw-rw- 1 ctuser users 1589 Jan 20 2010 sysstate.log.20100120_200549 insite@mvhogectrad02 log$ more sysstate.log.20110718_153958 . ================================================ Operation started : Tue Jan 5 20:26:28 2010 . ================================================ --------------------------------------------------- Save/Restore System State : Started PET Base Option Not Enabled ---> Enable this scanner as CT-only scanner Initializing DVD ... You have initiated a save operation! DVD initialization completed with Success Operation Save started: 2011-07-18 15:39:43 . Writing Version stamp in DVD for LightSpeed system Version Addition failed DVD completed with errors (-1) Releasing DVD ... DVD Release completed with Success Save/Restore System State : Completed with failures -------------------------------

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.