LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Fastcal scan aborts. Problem finding a calibration vector or calibration file.

Error message

Error: 230008150 During start-up recovery, a scan file is being moved instead of being deleted. See LD for details Mon Oct 2 00:35:17 2006 Error: 230008150 Host: erct1 Process: scanfilemgr File: sfm_server_api.c Line: 1053 Function: No system function reported Scan Type: Not scanning Scan: 22/7/4 During start-up recovery, a scan file is being moved instead of being deleted. Original name: /usr/g/data_management/ex22.ERCT.1159165948.649605/s7a4 New name: /usr/g/data_management/recovery/1159749317.540122.s7a4

Error: 230008155. During start-up processing, a scan header file was found on the system disk without a corresponding view data file on the high-speed disk. See LD for complete error Error: 230008155 Function: System Control : Scan Database Manager Scan Type: Not scanning Scan: 14681/2/1 During start-up processing, a scan header file was found on the system disk without a corresponding view data file on the high-speed disk. Scan: AJAX/14681/2/2

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required