GE Healthcare · CTLightSpeedVCT24521310700060100024504726010015217939
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Exposure Interlock aborted scanning. Exposure Interlock aborted scanning
Error message
Error: 245213 Scan was Paused/Aborted by Firmware (or the host) This is mostly a generic error See LD for error examples Error 245213 is a generic error caused by scan file manager Wed Apr 27 01:01:26 2005 Error: 245213 Host: ls16er Process: scanmgr File: scanmgr_events.cxx Line: 1617 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 107000 Scan was Paused/Aborted by Firmware You may also see another form of this error. Thu May 12 17:43:37 2005 Error: 245213 Host: rrmcct16 Process: scanmgr File: scanmgr_lib.cxx Line: 968 Function: System Control : Scan Control Scan Type: Scout Scan: 0/0/0 Scan Seq Id: 601000 Scan setup failed on Step:3 (Allocate Scan File). Status:245047 Another form of this error. Fri Jan 12 10:17:15 2007 Error: 245213 Host: ct10 Process: scanmgr File: scanmgr_events.cxx Line: 2318 Function: System Control : Scan Control Scan Type: Scout Scan: 0/0/0 Scan Seq Id: 4000 Scan was Paused/Aborted by Host Error: 260100152 Exposure Interlock Opened Please refer to the long description for further details. Fri Feb 8 18:12:19 2008 Error: 260100152 Host: tgp Process: tgp_subsys File: scIsrService.c Line: 386 Fri Feb 8 18:12:19 2008 Host : Tabl
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 10MW06.5 Titan for VCT (MUST HAVE SP1 or Higher) Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release) 10MW06.5 Titan for VCT Delivered via new install or FMI 25425 Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release)
- Area
- CT
Full cause & step-by-step resolution