GE Healthcare · MRSigna224832115642221962822236252248355
Several images would not reconstruct Due to ICN.
Symptom
Some or All Images in the Last Scan Did Not Reconstruct Some or All Images in the Last Scan Did Not Reconstruct.
Error message
2248321 Communication Error. The callback for SCSM state 0x4 was not received in time. The DP server is not responding, the server might be hung. Please perform a TPS reset to recover.-> 2248321 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: VIBRANT Coil: 8Brst BL SMI Scan: 15642/6 Communication Error. The callback for SCSM state 0x4 was not received in time. The DP server is not responding, the server might be hung. Please perform a TPS reset to recover.-> 2219628 The BAM Check Packet failed to reach the TPS Tue Jun 15 08:58:55 2004 Error: 2219628 Host: IRIS Process: scn File: SrxIPScreen.m Line: 1956 The BAM Check Packet failed to reach the TPS. 2223625 Send packet opcode:192 seqnum:2673 rev:2 type:1 length:36 req:SCAN_01_NOR resp:RECN_00_NOR status:0 failed. 2223625 Exception Class: Unknown Function: Software/Firmware: Host Communications Send packet opcode:192 seqnum:2673 rev:2 type:1 length:36 req:SCAN_01_NOR resp:RECN_00_NOR status:0 failed. 2248355 AGP to SCP State Error. SCT received a wavegen status 3 in a non-wavegen state 3 It may be necessary to perform a TPS reset. Error: 2248355 Host: hopgemr1a Process: NSP File: SCP:sct_mct
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- SecondOpinion Image Compute Node 5127452 See comments in Resolution Concept for second opinion requirements before ordering this part.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.