GE Healthcare · MRSigna22626012262603
Table doesnt raise intermittently with table errors 2262603 and 2262601 due to defective PHPS.
Symptom
Table intermittently doesn't raise with several errors, 2262603 A Fault was detected on the Table Motor Controller and 2262601 A Fault was detected on the Table DC Power Supplies . Table intermittently doesn't raise with several errors, 2262603 A Fault was detected on the Table Motor Controller and 2262601 A Fault was detected on the Table DC Power Supplies.
Error message
2262601 A Fault was detected on the Table DC Power Supplies. Tue Apr 7 07:49:35 2009 Error: 2262601 Host: BROCKGEMR78 Process: NSP File: SCP:PhpsHWO Line: 625 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Longitudinal Motion PSD: T2flair Coil: HEAD Scan: 1511/9 A Fault was detected on the Table DC Power Supplies. 2262603 A Fault was detected on the Table Motor Controller Tue Apr 7 07:49:35 2009 Error: 2262603 Host: BROCKGEMR78 Process: NSP File: SCP:PhpsHWO Line: 638 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Longitudinal Motion PSD: T2flair Coil: HEAD Scan: 1511/9 A Fault was detected on the Table Motor Controller.->
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 5215012 MR Patient Handling Power Supply see long description 5215012 MR Patient handling power supply for assembly for MR excite 3. This is identical to the 5109368 assembly but has power supplies with a modification to allow operation upto a 200 Gauss magnetic field.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.