GE Healthcare · CTLightSpeedVCT
LightSpeed 1.X - GRE
Symptom
Gantry emergency off keeps activating on its own intermittently.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 1.X - GRE H1_P_S4 Lightspeed 1.X - GRE Method of visual identification Large square gantry similar in appearance to a CTi gantry. Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2236720-2 COVER TABLE TOP - RIGHT - used on Zeus table See Long description for details Part #: 2236720-2 Part Type: GP CONSUMABLES Part Weight: 25.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER ASSEMBLY TABLE TOP - RIGHT FRU: Yes Status: Orderable Comments: FLS - COVER ASSEMBLY TABLE TOP-RIGHTU/O LIGHTSPEED & PET TABLE 6/30/99 MS08992 THIS REPLACED THE 2149735 PER CHRIS DOERING MSA1248 10/99 GPC TABLE MOVED TO CHINA 5/24/01 NOW ASIA SOURCED THIS P/N HAS BEEN REPLACED BY P/N 2372372 (ONLY APPLICABLE ON HPOWER SYSTEMS) PER PCN 220864. MS20544 3/31/03. DIMS: 90" LONG; 70" WIDE FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required