LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Shutdown Scanner HW Shutdown
Error message
Error: 260111018 GUIF communications are down. Need a display and at least one control. See long description for full sample error. Tue May 6 12:11:16 2008 Error: 260111018 Host: tgp Process: tgp subsys File: guif can mgr2.c Line: 3866 Tue May 6 12:11:15 2008 Host : Table Gantry Processor Ermes # : 260111018 Exception Class : Safe State Severity : Primary File : guif can mgr2.c Line# : 3866 Function : OPERATOR INPUT/OUTPUT : Gantry Operator Interface Scan Type : None/Unknown Scan: 0/0/0 GUIF communications are down. Need a display and at least one control. Error: 260111021 GUIF CAN node response timeout See LD for details Wed Apr 4 16:55:13 2007 Error: 260111021 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 1453 Wed Apr 4 16:55:13 2007 Host : Table Gantry Processor Ermes # : 260111021 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 1453 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : None/Unknown Scan: 9106/1/0 GUIF CAN node response timeout. Node part number 2256730. Node serial number 32636. Node CAN ID# 1.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 10MW06.5 Titan for VCT (MUST HAVE SP1 or Higher) Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release) 10MW06.5 Titan for VCT Delivered via new install or FMI 25425 Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release)
- Area
- CT
Full cause & step-by-step resolution