GE Healthcare · MRSigna2247384185712247386224816322482172847174
Will not scan with error 2248217 Receiver calibration error Due to Receiver Board.
Symptom
Will not scan with error 2248217 Receiver calibration error Fri Jul 18 05:59:36 2003 2248217 4b2a diagCoord RrfCalibrator::rcvCal 3779Diagnostic: RRF Calib Iteration: 32 of infinite Action: 1Task ID: 0x9d29e0 Time: 2847174 Object: APSReceiver calibration error(s). Receiver DB out of spec.R1 values that failed:Rx1: 12 10Rx2: 12 11 10 9Rx3: 12 11 10 9Rx4: 12 11 10Rx5: 12 11 10 9Rx6: 12 11 10 9Rx7: 12 11 10 9Rx8: 12 10
Error message
2247384 Diagnostic error. The signal's energy level is severely below the what is expected. See Long Description 2247384 tempmr diagCoord rrfRxFruIso.c 1539 Diagnostic: 16 Channel Switch Iteration: 1 of 1 Action: 1 Task ID: 0x3fa6a60 Time: 18571 Object: APS Test Task Test: '16 Ch Switch Input Osc. AB, Port A' diagnostic error. The signal's energy level is severely below the what is expected. 'Dead' channels are: 1-8-> Extended Error: Sys Cab and UTNS Bypass Diag: Dead channels while running these diags indicate a problem with a board in the receive chain (MUX, UTNS, Rx), or cables between the boards. Sixteen bad channels (or eight bad channels in an eight channel system would indicate a problem with the signal source, or problems other than the three receive chain boards. Eight bad channels in a 16 channel system would indicate a bad board. Swapping good boards with suspected boards is an effective way to isolate a problem. Problems with banks of channels (1-4, 5-8, etc) may indicate a problem with a receive When individual bad channels (1,8,9,16) may lead to an improperly seated cable.\n 16 Channel Switch diag: If problems exist when running this diagnostic, the Sys Cab Loopback d
Applies to
- Models
- Signa
- Product
- 3.0T Signa HDxT For 3.0T Signa HDxT systems with 15.0 software only. For 3.0T Signa HDxT systems with 15.0 software only.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 5250094 RECEIVER 2A BOARD 5250094 RECEIVER 2A BOARD
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.