GE Healthcare · CTLightSpeedVCT2601010985000126010105724463426011801150075

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scan hardware stopped scan with RCIB errors

Error message

Error: 260101098 A fault line failure has been detected. Scanning is disabled. Repair the fault line between the ORP and sub-sytem before continuing. See Long Description for complete error Wed Apr 27 01:01:26 2005 Error: 260101098 Host: orp Process: orp_subsys File: rcib_misc.c Line: 425 Wed Apr 27 01:01:25 2005 Host : On-Board Rotating Processor Ermes # : 260101098 Exception Class : Soft Severity : Pri/Soft File : rcib_misc.c Line# : 425 Function : No System Function Reported Scan Type : Axial Scan: 50001/1/1 A fault line failure has been detected. Scanning is disabled. Repair the fault line between the ORP and sub-sytem before continuing.

Error: 260101057 RCIB Fault Line failure detected This Error has variables - See LD for details Error: 260101057 RCIB Fault Line failure detected Error Example: (see below for explanation ) Tue Jan 3 11:05:44 2006 Host : On-Board Rotating Processor Ermes # : 260101057 Exception Class : Secondary Severity : Pri/Soft File : rcib_fault_status.c Line# : 189 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 RCIB Fault Line failure detected. The status of the fault bus is as follows: Parallel or Serial Fault line: [1=Fault 

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.