GE Healthcare · CTLightSpeedVCT260125041900824897741749120
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260125041 Motion without command in Elevation drive See LD for more details Wed Jun 14 12:48:32 2006 Error: 260125041 Host: tgp Process: tgp_subsys File: ta_callback_gt.c Line: 508 Wed Jun 14 12:48:31 2006 Host : Table Gantry Processor Ermes # : 260125041 Exception Class : Abort Severity : Primary File : ta_callback_gt.c Line# : 508 Function : No System Function Reported Scan Type : Helical Scan: 412/4/1 Motion without command in Elevation drive Current pos = 900824 Last stop pos = 897741 Tolerance = 3000 Time since last stop = 749120 Last target pos = 1 Hardware status = 0
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5138908 TABLE SUPPORT TOOL JIG ASSY - used on Global tables See long description for details Part #: 5138908 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: TABLE SUPPORT JIG ASSY FRU: Yes Status: Orderable Comments: Not Available 5127285 SHUT OFF VALVE ASSY used on GT1700 and GT2000 table See Long Description 5127285 SHUT OFF VALVE ASSY used on GT1700 and GT2000 table Part #: 5127285 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: SHUT OFF VALVE ASSY Positoning GT FRU: Yes Status: Orderable Comments: Not Available 2227239 Hydraulic fluid (crosses to P/N Z9807QD, .5 L Hydraulic Oil) See Long Description for details 2227239 Hydraulic fluid (crosses to P/N Z9807QD, .5 L Hydraulic Oil) Part #: Z9807QD Part Type: GP CONSUMABLES Part Weight: 3.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: 0IL ASSY FRU: Not Available Status: Orderable ====================== Parts Offered as: Current: Z9807QD Harvested: Not Available Exchange: Not Available Comments: FLS - PLEASE ORDER AS YMSZ9807QD MS13452 5127284-3 (replaces 5127284) PROPORTIOAL VALVE ASSY Positoning GT - FRU yes - this assembly contains two proportional valves. See Long Description for details and picture: Part #: 5127284-3Part Type: GP CONSUMABLES Part Weight: 0.00 LBRRepairable: NoReturnable: NoHazardous Material: NDescription: PROPORTIOAL VALVE ASSY Positoning GTFRU: YesStatus: Orderable Comments: added per to ECO2079401 by sso#305010201 in Jun 8, 2009 Part #: 5127284 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: PROPORTIOAL VALVE ASSY Positoning GT FRU: Yes Status: Orderable Comments: Not Available This part is actually an assembly - the assembly contains two proportional valves and wire cable harness assembled/wired together. GT
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.