LightSpeed RT16 & RT16 Xtra and Vision
Symptom
Pop-Up Attention Box recommending SPECIAL FastCal be run. See Long Description for details. Customer will see attention box when Special FastCal required. RT16 Special FastCal required with the release of FMI 22918 sw_version: 08BW17.7 TUBE WARM UP AND CALIBRATION To optimize image quality and workflow, a SPECIAL FastCal procedure has been implemented which runs on specified date to replace the previous 75-minutes-interval Warm Up attention message customer was seeing thoughout the day. The following procedure is recommended. FastCal – the normal FastCal should be performed once per day. A SPECIAL FASTCAL – A SPECIAL FastCal will be required once every 4 weeks to ensure the equipment is in the best condition. When the Attention Box of SPECIAL FastCal pops up, SPECIAL FastCal must be executed after the tube temperature is completely cool, then it takes less than 30 minute to complete the calibration process. The Attention Box will show up from the beginning of the fifth week since the last SPECIAL FastCal and it will keep popping up every 6 hours during the whole fifth week until this action is taken. Otherwise, only large focus is available for scanning beginning in the sixth week. A SPECIAL FastCal will use same button with the current “ Fast Cal”. Note: The customer is NOT required to run the SPECIAL Fastcal at this time. They have ONE week to perform this calibration. If you have the customer perform the calibration at this time, they will have to wait 2 hours and 45 minutes for tube cooling if they have been scanning prior to the pop up message. The recommendation should be to run the Special FastCal first thing in the morning when tube is cold, thereby eliminating the need for tube cooling. It is IMPORTANT to remind them to NOT Warm up the tube, and go directly to the Fast Cal button. The Fast Cal button will look different during week Five when the Special FastCal should be run. Do not click “Tube Warm up” when you decide to run the SPECIAL FASTCAL. Select “OK” to hide the Attention Message Box and then click “ Fast Cal” button. If click “ OK “ , the Attention Box will post indicating remaining tube cooling time. When waiting time counts down to 0 minute, click “OK” again and then desktop will switch to SPECIAL FastCal desktop. If click “cancel” , the Attention Message Box will disappears and desktop will switch to Normal FastCal desktop automatically. If click “ Quit” , the Attention Message Box will disappear and the system returns to the Daily Prep window. Please note: Do not pause X-ray exposure during the SPECIAL FastCal is in progress. Otherwise, the fastCal may fails .
Error message
Error: 200110043 Could not access air ratio cal db file .arcal See long description Thu Apr 7 17:11:59 2011 Error: 200110043 Host: ct01 Process: scanRx File: ZeusrpGlobalActions.cLine: 1862 Function: Data Acquisition : OC Processing Could not access air ratio cal db file .arcal. The file is either missing or zero size. Unable to determine when need to run air ratio cal. Large spot only for patient scanning
Applies to
- Models
- LightSpeed
- Product
- LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 10BW27.7 Software for BSD Delight (AIO Console) and RT16 Vision See Long Description 10BW27.7 Software for BSD Delight (AIO Console) and RT16 Vision This software was released via FMI 22926 FMI Title: 10BW27.7 Software Release for BSD Delight and RT16 Vision Furnished Materials FMI22926 Kit (Part Number: 5407235): Items Part Number Part Description 5407235-1EN FMI 22926 Instruction (Hard Copy) 5408645 10BW27.7 jewel case 5405943 OS 6.3.8 (DVD) 5405944 App (DVD) 5407148 SOL (CD) 5407135 SP1.0 for 10BW27.7 (CD) 5390977-1EN SP2.0 Common Addendum TWA_English (Hard Copy) 5390977-299 SP2.0 Common Addendum TWA_Muli-language (CD) • 5405945- Class C (Tab #182) • 5405946- Class M (Tab #182)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required