GE Healthcare · CTLightSpeed200501547200001821200501533200600025
LightSpeed 4.X - GRE
Symptom
Software hungup after exam was paused
Error message
Error: 200501547 A Communication Error has occurred in uifIpcSendRecvPriorityReconRequest See Long Description for Details Sat Mar 21 12:04:36 2009 Error: 200501547 Host: ct01 Process: scanRx File: uifIpcMgrScanRx.c Line: 9900 Function: Data Acquisition : OC Processing A Communication Error has occurred in uifIpcSendRecvPriorityReconRequest with seq_n um = 947 and status = 200001821 ERROR: 200501533 Event Router process with status: Timed out while attempting to receive a message.. See LD for variations of this error. ERROR: 200501533 Process Timed out while attempting to receive a message. Wed Feb 28 17:51:14 2007 Error: 200501533 Host: ct99 Process: scanRx File: uifIpcCommonFunctions.c Line: 2270 Function: No system function reported Service uif_scan_rx failed to receive message with event code 3141 from Event Router process with status: Timed out while attempting to receive a message. Below is another example of a different process that timed out: Fri Dec 30 10:03:25 2005 200501533 4 ctls16 reconMgmt uifIpcCommonFunctions.c 2269 Function: No system function reported Service uif_recon_mgmt failed to receive message with event code 3123 from Event Router process with status: Time
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required