Lightspeed 1.X - Octane

Symptom

Gantry table controls would not work when moving patient into the gantry. Footpedals would move table up/down.

Error message

Error: 182219 HW error: Home latch driver fault detected by hardware (SMART switch). See LD for Complete Error Fri Jun 3 15:23:41 2005 182219 2 HICT ETC Cradle cmcControl.c 1.23 2/16/99 No Method 296 Function: PATIENT ANATOMY POSITIONING : Cradle Drive Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 15:23:42:230 Log Series: 44 HW error: Home latch driver fault detected by hardware (SMART switch).

Applies to

Models
LightSpeed
Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2225306 GANTRY CONTROL PANEL - RIGHT SIDE U/O HELIOS GANTRY See Long Description Part #: 2225306 Part Type: GP CONSUMABLES Part Weight: 1.81 LBR Repairable: No Returnable: No Hazardous Material: N Description: GANTRY CONTROL PANEL - RIGHT SIDE FRU: Yes Status: Orderable
Area
CT