GE Healthcare · CTLightSpeedVCT200600063
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
When selecting a cardiac scan series in Retro Recon get pop up attention error that says: System could not connect to ECG Editor. Please exit retroRecon and try again. See long description for a picture of the error message. When selecting a cardiac scan series in Retro Recon get pop up attention error that says: System could not connect to ECG Editor. Please exit retroRecon and try again.
Error message
Error: 200600063 Unable to send EV_SAVE_RPEAKS_ON_RETRO_CONFIRM to EKGBroker. Images may not be accurate. See Long Description Tue Aug 4 18:15:48 2009 Error: 200600063 Host: vct1 Process: retroRecon File: UIRxToRetroRequest.cxx Line: 2450 Unable to send EV_SAVE_RPEAKS_ON_RETRO_CONFIRM to EKGBroker for E32702/S301/I1. Images may not be accurate.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 09MW08.11 for GOC6 LightSpeed VCT 7.2 (64 Slice Only) . This software is now obsolete, this site should be upgraded to 11HW12.5 software released via FMI 25427 09MW08.11 for GOC6 LightSpeed VCT 7.2 (64 Slice Only) Vision Refer to SN09051913a LightSpeed 7.2 ( 09MW08.11 ) Software Release supports GOC6 consoles used on VCT 64, VCT XT, VCT XTe and VCT Std. - LightSpeed 7.2 (09MW08.11 )Software for GOC6 Collector 5311595 Rev 3 Includes OS and Application CD's - Operating System Linux 5.3.8 Software CD 5323584 Rev 1 - Application LightSpeed VCT GOC6 DVD 5336533 Rev 3 - Class C LightSpeed 7.2 5336535 Rev 2 - Class M LightSpeed 7.2 5336536 Rev 2 An On-site/Remote identification aid . (Example: check_config) Result from check_config or swhwinfo 09MW08.11.V40_H_V64_G_GTM Please create an ITRAK report for any software related issues
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.