Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT1786016095615000245051173001

LightSpeed 3.X (Ultra, Plus, QX/i) - GRE

Symptom

Unable to do a tube warm-up. Unable to do a tube warm-up

Error message

Error: 178601 Timed out waiting for CF query response See Long Description Mon Nov 23 12:59:34 2009 Error: 178601 Host: ls01 Process: fwmgr File: CF.c Line: 1910 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Timed out waiting for CF query response. Msg code sent to fw: 60956 Response message code: 7407 FW mail box: 10 Response message descriptor: 1 (See process.timers for mapping message descriptor to UUID.) Timeout: 15000

Error: 245051 Error verifying that Firmware Manager is ready for scanning. See LD for details Wed Oct 4 15:30:39 2006 Error: 245051 Suite: SKCT Host: SBC0 Process: scanmgr File: start_scanning.m 1.34 Method: start_scanning() Line: 306 Function: Data Acquisition : SBC Processing Scan: 6019/1/1 Type: Scout Scan Seq: 173001 Error verifying that Firmware Manager is ready for scanning

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution