GE Healthcare · CTLightSpeedVCT182825182872105252372485182826182886
LightSpeed 4.X - GRE
Symptom
Customer was not able to remote tilt gantry. In many cases , gantry will tilt from the Gantry Controls.
Error message
Error: 182825 Communication Problems with the GANTRY CONTROL See Long Description for full error Tue Dec 1 17:17:45 2009 Error: 182825 Host: ETC Process: Gantry Display File: gd_tnc_driver.c Line: 471 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 17:17:39:290 Log Series: 11 HW/SW error: Communication Problems with the GANTRY CONTROL. Number of Communication Timeout errors: 3. Number of NACK''s errors: 0. Number of DUART errors: 0. Numver of Checksum errors: 0 Error: 182872 TNC Controller Received an Invalid Command. See LD for more details Error: 182872 TNC Controller Received an Invalid Command. Thu May 25 08:19:06 2006 Error: 182872 Host: ETC Process: Gantry Display File: gd_tnc_erlog.c Line: 505 Function: No System Function Reported Scan: 10525/2/2 Type: Helical Exception Level: Pri/Soft Time: 08:19:06:480 Log Series: 140 TNC Controller Received an Invalid Command. Message Code: 7 Current State: 1. Board Number: 2372485 Serial Number: 0. Error: 182826 Communication Error: Communication Packet with the GANTRY DISPLAY. Open Long Description for full error Wed Dec 22 20:49:26 2004 Error: 182826 Host: ETC Process: Gantry Displ
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required