GE Healthcare · CTLightSpeedVCT26013274750043260132509
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260132747 Digital Interface Board(s) Failed To Write An ASIC Trim Table See LD for complete error Mon Oct 31 07:18:06 2005 Error: 260132747 Host: orp Process: orp_subsys File: Ifb.cxx Line: 504 Mon Oct 31 07:18:06 2005 Host : Das Ermes # : 260132747 Exception Class : Secondary Severity : Sec/Soft File : Ifb.cxx Line# : 504 Function : No System Function Reported Scan Type : Axial Scan: 50043/5/7 Digital Interface Board(s) Failed To Write An ASIC Trim Table DIFB : 4 Digital Module: 6 ASIC : 23 Error: 260132509 DCB has detected IFB Rx FIFO Fill error(s). See LD for complete error Mon Feb 13 14:26:30 2006 Error: 260132509 Host: orp Process: orp subsys File: Acquisition.cxx Line: 1701 Mon Feb 13 14:26:29 2006 Host : Das Ermes # : 260132509 Exception Class : Abort Severity : Secondary File : Acquisition.cxx Line# : 1701 Function : No System Function Reported Scan Type : Scout Scan: 2105/2/1 Scan ABORT -- DAS Has Detected An Error. The DCB has detected Ifb Rx FIFO Fill error(s). Skew 0: 0xffffffff Skew 1: 0x0fffcfff Skew 2: 0xffffffff Skew 3: 0x00ffffff
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required