Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT

LightSpeed 3.X (Ultra, Plus, QX/i) - GRE

Symptom

Phantom Holder is bent, broken, cracked, or damaged See long description and must be replaced.

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2331933 METALLESS PHANTOM HOLDER 2331933 METALLESS PHANTOM HOLDER Part #: 46-222986G2 Part Type: GP CONSUMABLES Part Weight: 5.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: METALLESS PHANTOM HOLDER FRU: Yes Status: Orderable Comments: FLS - DESC: METAL-LESS COMPATIBLE PHANTOM HOLDER. THE 46-222986G2 IS NOT A DIRECT REPLACEMENT FOR THE G1 (G2) IS METAL-LESS. ALSO PINHOLDER ON THE CRADLE MOUNT MUST BE REMOVED FROM THE G1 AND PUT ON THE G2 IN ORDER TO BE ABLE TO USE THE G2 IN PLACEOF THE G1. IF THE PINHOLDER ON THE G1 IS DEFECTIVE, THE GE WILL NOT BE ABLE TO BE INSTALLED. 1/9/97 GWENN 08992 ALSO USED ON HINO CT/E PINHOLDER IS 46-222987G1 P/N 46-222986G2 WILL BE REPLACED BY P/N 2331933 (ASIA SOURCED) PER PCN 220526. USE EXISTING STOCK FIRST. ADDED BY MS20544 ON 6/9/02.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues