Pular para o conteúdo principal
GE Healthcare · CTDiscoveryVCT26012101220606

Gantry tilt moves a small distance then stops (less than 2 deg)

Symptom

Gantry tilt moves a small distance then stops (less than 2 deg) Gantry tilts forward a small distance then stops

Error message

Error: 260121012 Gantry velocity greater than the Maximum allowed velocity. Gantry velocity:2004 mdeg/sec Current tilt position:-20606 mdeg Maximum allowable velocity:2000 mdeg/sec Error: 260121012 Host: tgp Process: tgp_subsys File: tilt_mgr.c Line: 1143 Sat Apr 30 06:22:02 2005 Host : Table Gantry Processor Ermes # : 260121012 Exception Class : Soft Severity : Pri/Soft File : tilt_mgr.c Line# : 1143 Function : No System Function Reported Scan Type : Scout Scan: 1779/3/1 Gantry velocity greater than the Maximum allowed velocity. Gantry velocity:2004 mdeg/sec Current tilt position:-20606 mdeg Maximum allowable velocity:2000 mdeg/sec

Applies to

Models
Discovery, VCT
Product
Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues