Intermittent MDS Link Failures due to Fiber Optic MDS Link Cable from Tyme to Gradient Cabinet.
Symptom
Intermittent MDS Link Failures while Scanning. Getting MDS link failures while scanning. Reports error 2241608 GIP VCC signal is out of range. Note that the value was mere millivolts out of spec, but enough to trip out scans. I measured the voltage at 4.81 volts, nominally low, but barely in spec. Spec is: Low: 4.70V High: 5.250V.
Error message
2225693 MDS link failure. An MDS device failed to respond to IPG. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. Timer: 254 MDS header: 0x11 -(00/10 = Grad, 01/11 = RF Cabient) MDS opcode: 0x0B 2225693 lx-mr NSP HPC_PORT_ID:spi_mds 503 MDS link failure. An MDS device failed to respond to IPG. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. Timer: 254 MDS header: 0x11 -(00/10 = Grad, 01/11 = RF Cabient) MDS opcode: 0x0B 2225699 MDS link failure. An MDS device failed to respond to IPG on a 2nd try. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. Timer: 509 MDS header: 0x11 -(00/10 = Grad, 01/11 = RF Cab) MDS opcode: 0x0B 2225699 lx-mr NSP HPC_PORT_ID:spi_mds 509 MDS link failure. An MDS device failed to respond to IPG on a 2nd try. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. Timer: 509 MDS header: 0x11 -(00/10 = Grad, 01/11 = RF Cab) MDS opcode: 0x0B
Applies to
- Models
- Signa
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Component
- 46-317249G25 LX SGD FIXED SITE FIBEROPTIC SYS CBL 46-317249G25 LX SGD FIXED SITE FIBEROPTIC SYS CBL FLS - FIBER OPTIC CABLE COLLECTOR MS3571 11/27/98
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.