GE Healthcare · CTLightSpeed2300065302508800000080000023000906710989
LightSpeed 3.X (Ultra, Plus, QX/i) - Octane
Symptom
Customer is not able to delete a corrupted recon queue entry. CU is not able to delete a corrupted recon queue entry
Error message
Error: 230006530 RECON_JOB_FAILED_RETRY See Long Description for complete error Tue Feb 1 06:33:34 2005 Error: 230006530 Host: ice Process: reconmgr File: rm_recon_mgr.c Line: 1114 Function: Image Generation : SBC Processing Job Type: Prospective Axial Scan: 25088/2/9 Image: 25088/3/25 Recon Seq Id: 957 RECON_JOB_FAILED_RETRY : number_detector_macro_rows 4 collimation_mode 0 num _rows_used_per_image 1 vw_mode -1 zsmooth_factor 1.000000 ibo 1 tilt 0.000000 gantry_period_sec_rev 0.800000 Error: 230009067 Retry queue entry See Long Description for error example. Tue Oct 19 09:24:04 2004 Error: 230009067 Host: dgct Process: queuemgr File: qmgr_list_mgmt.c Line: 2217 Function: Image Generation : SBC Processing Job Type: Prospective Helical Scan: 10989/2/1 Image: 10989/2/1 Retry queue entry Error: 230006529 Recon Mgr is sending queue ack to queuemgr with a RECON_JOB_FAILED_RETRY status See Long Description for Full Error Tue Feb 1 06:33:34 2005 Error: 230006529 Host: ice Process: reconmgr File: rm_recon_events.c Line: 329 Function: Image Generation : SBC Processing Job Type: Prospective Axial Scan: 25088/2/9 Image: 25088/3/25 Recon Seq Id: 957 Recon Mgr is sending queue ack to queuemgr
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required