Pular para o conteúdo principal
GE Healthcare · CTBrightSpeedLightSpeed260134604

BrightSpeed HPower, Delight, Velocity or MERI HPower

Symptom

Difficulty in positioning the cradle. Cradle will not drive normally and scan aborts with errors.

Error message

Error: 260134604 Cradle Motion Control task received invalid command.messageCode = 5120 current state = 3 See LD for more details Error: 260134604 Cradle Motion Control task received invalid command.messageCode = 5120 current state = 3 Fri May 5 09:38:39 2006 Error: 260134604 Host: tgp Process: tgp subsys File: gtcb cmc.cxx Line: 256 Fri May 5 09:38:39 2006 Host : Table Sub-System Ermes # : 260134604 Exception Class : Secondary Severity : Pri/Soft File : gtcb cmc.cxx Line# : 256 Function : No System Function Reported Scan Type : None/Unknown Scan: 928/2/0 Cradle Motion Control task received invalid command. messageCode = 5120 current state = 3

Applies to

Models
BrightSpeed, LightSpeed
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required