LightSpeed RT16 & RT16 Xtra and Vision

Symptom

Attention: The Scanning Hardware is not available. Please see long description. Attention: The Scanning Hardware is not available, please wait for the hardware reset successfull status posted in the feature status area on the right monitor. If the hardware reset fails, then reset the scan hardware from the Service Desktop System Resets button.

Error message

Error: 260107207 Axial Motor Control (AMC) logic will NOT accept commands in Shutdown Mode of Operation. A RESET of the Scan Hardware is required and try again See the LD for the complete error code. Error: 260107207 Axial Motor Control (AMC) logic will NOT accept commands in Shutdown Mode of Operation. A RESET of the Scan Hardware is required and try again Mon Jan 8 06:43:28 2007 Error: 260107207 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 3957 Mon Jan 8 06:43:27 2007 Host : Table Gantry Processor Ermes # : 260107207 Exception Class : Abort Severity : Primary File : amc_mgr.c Line# : 3957 Function : No System Function Reported Scan Type : None/Unknown Scan: 50001/1/0 Axial Motor Control (AMC) logic will NOT accept commands in Shutdown Mode of Operation. A RESET of the Scan Hardware is required and try again. (Cmd: 24).

Applies to

Models
LightSpeed
Product
LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
08BW44.1 Software for all BrightSpeed Systems with AIO Console and all RT16 Systems with GOC4 Console See Long Description 08BW44.1 Software is used on all BrightSpeed Systems with AIO Consoles and all RT16 Systems with GOC4 Consoles. Software collector called “08BW44.X” p/n 5328867 contains the following items: 5323837 - LightSpeed Xtream Console Operating System Version - GEMS Linux 6.3.8 5323838 - LightSpeed Applications Software DVD Version 08BW44.X 5328828 - Xtream Serial-Over-LAN Service Software Version - 2.0 Supports: Westville or Jarrell DARC/VDARC 5323839 - Class C 5323840 - Class M NOTE: Class C/M install CD are not shipped with system. NOTE: The Xtream Serial-Over-Lan Service Software is not used during the LFC unless instructed via a pop-up message box "SOL Service - ...run the Serial Over LAN Service CD...". This CD is loaded directly into the DARC Node. Then press the reset (or cycle power) at the front panel of the DARC Node as required. This CD will auto-eject when the SOL load process is complete. NOTE: The Xtream Serial-Over-Lan CD is not used for All-In-One Console.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.