GE Healthcare · CTLightSpeed200350195
LightSpeed 4.X - GRE
Symptom
No Gantry Display or only 3 green dots are seen in the display No Gantry Display and only 3 green dots are seen in the display
Error message
Error: 200350195 Unexpected message descriptor received when opening a UUID XXX See the LD for the full error codes Error: 200350195 Unexpected message descriptor received when opening a UUID XXX Mon May 10 16:44:42 2004 Error: 200350195 Host: ct01 Process: coordinator File: new_coord_main.c Line: 3744 Running Version Management Tool Function: System Communications : Control Network Test: Version Management Tool Test status: starting Unexpected message descriptor received when opening a UUID mail box. UUID: 160 (OBC HOP) Message descriptor: 2122 Sun Oct 29 15:46:48 2006 Error: 200350195 Host: ct02 Process: coordinator File: new_coord_main.c Line: 3749 Running Version Management Tool Function: System Communications : Control Network Test: Version Management Tool Test status: starting Unexpected message descriptor received when opening a UUID mailbox. UUID: 220 (STC Axial) Message descriptor: 2122
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required