Symptom
Scanner Hardware Reset Failed. See LD Scanner Hardware Reset Failed Hardware Failed to reset message appeared on monitor AFTER boot-up WITH Error:178568 Failed to establish socket connection to STC in 10 seconds and errors 244553 and 244554 and power up self test fails A, B, and 9 on STC CPU board The following errors were in the gesyslog Thu Jan 13 04:18:32 2005 Error: 178568 Suite: RP25 Host: SBC0 Process: fwmgr File: NBSSocket.m 1.9 Method: connectToTarget Line: 315 Failed to establish socket connection to STC in 10 seconds Thu Jan 13 04:18:32 2005 Error: 244553 Suite: RP25 Host: SBC0 Process: fwmgr File: HwSetUp.m 1.18 Method: hardReset Line: 429 The STC controller has failed to reset. Thu Jan 13 04:18:32 2005 Error: 244554 Suite: RP25 Host: SBC0 Process: fwmgr File: HwSetUp.m 1.18 Method: hardReset Line: 442 The reset failure of the OBC may be due to the reset failure of the STC. Also saw failures A, B, and 9 on the power-up test on the STC CPU .
Error message
Error: 260110005 The DAS/collimator firmware object had a timeout waiting for message 3003 See long description for full errors Sat Mar 21 19:14:02 2009 260110005 orp orp_subsysdas_event_mgr.cxx 1884Sat Mar 21 19:14:01 2009Host : On-Board Rotating Processor Ermes # : 260110005Exception Class : Secondary Severity : Pri/SoftFile : das_event_mgr.cxx Line# : 1884Function : No System Function ReportedScan Type : None/Unknown Scan: 0/0/0 The DAS firmware object had a timeout waiting for message 18 Sat Mar 21 19:14:02 2009 260110005 5 orp orp_subsyscoll_event_mgr.c 1357Sat Mar 21 19:14:01 2009Host : On-Board Rotating Processor Ermes # : 260110005Exception Class : Secondary Severity : Pri/SoftFile : coll_event_mgr.c Line# : 1357Function : No System Function ReportedScan Type : None/Unknown Scan: 0/0/0 The Collimator firmware object had a timeout waiting for message 18 Error: 260101090 The DCB was shutdown due to an error. Scanning is disabled. A controller reset is required to continue. 1095852111 0 1 Wed Sep 22 11:21:51 2004 260101090 4 orp orp_subsys rcib_misc.c 294 Wed Sep 22 11:21:50 2004 Host : On-Board Rotating Processor Ermes # : 260101090 Exception Class : Abort Severity : Seconda
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required