Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system…

VRE Errors Due to ICN.

Symptom

Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.

Error message

2249418 Network problem detected. Check MGD subnet network configuration. See Long Description Wed Apr 14 09:27:10 2004 2249418 2 CARD diagCoord mgdArp.c 157 Task ID: 0xf99df8 Time: 981 Object: SCP Network problem detected. Check MGD subnet network configuration. etherAddrResolve failed for network interface motfec0, IP 10.47.1.2, numTries 5, delay 100 ticks. status = -1.

2249436 Host Communications Communication Problem Between APS And VRE Mon Oct 8 08:30:39 2007 Error: 2249436 Host: LJP MR 01 Process: diagCoord File: cm init.c Line: 293 Task ID: 0x6d89800 Time: 2376 Object: APS Exception Class: Unknown Function: Software/Firmware: Host Communications Communication problem between APS and VRE. The APS could not notify the VRE that communication is established.

2227603 VRE reset failed due to failure to communicate with all ICNs! Check Ethernet and IPMI connectivity to all ICNs see long Error: 2227603 Host: SJH_MR1 Process: insite_msg Host: SJH_MR1 Process: NSP File: VREReset.cc Line: 764 Exception Class: Unknown Function: Recon: Data Acquisition VRE reset failed due to failure to communicate with all ICNs! Check Ethernet and IPMI connectivity to all ICNs.->

2223859 The TPS Rese

Applies to

Models
Signa
Product
Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
Software
15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
Component
SecondOpinion Image Compute Node 5127452 See comments in Resolution Concept for second opinion requirements before ordering this part.