LightSpeed 5.X (80/100kW)

Symptom

Oil found coming out of Gantry Base. IMPORTANT: See Long Description Oil found coming out of Gantry Base. Contact Tubes for Major Oil Leak Recommendations Ryan August 414 - 745 - 8127 or Tom Hurdis 262 - 510 - 5782 or John Breunissen 414 - 202 - 9485 Encourage Warm-ups NOT use of lower mA Verbiage in the Operator Console (OC) messaging has changed from “ should ” to “ must ” as shown below. Additional information in customer documentation advises “ Tube Warm-Up takes 72 seconds to complete. Failure to perform Tube Warm-Up when requested may cause serious equipment damage and decrease tube life. ” Failure to perform the warm-up would be classified as a “violation of GE Healthcare’s recommendations or instructions on use” and is disclaimed in the Tube Warranty. (See “Limitations” section excerpted from the Tubes Warranty document and printed below.

Error message

Error: 260118275 (110-0903) Tube casing temperature has exceeded 92 degree C See LD for more details Sun Nov 6 12:44:33 2005 Error: 260118275 Host: orp Process: orp_subsys File: gen_exec.c Line: 2150 Sun Nov 6 12:44:32 2005 Host : Jedi Ermes # : 260118275 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2150 Function : No System Function Reported Scan Type : Static Scan: 50108/1/3 (110-0903)Tube casing temperature has exceeded 92 degree C.^C Z6,Z7= 0h,0h

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
D3194T PERFORMIX PRO-100 TUBE UNIT - Monopolar Hercules Tube used on 5.X (80/100), LS RT16, 7.X See Long Description for Details D3194T PERFORMIX PRO-100/VCT, RT16 and RT16 Xtra TUBE UNIT - Monopolar Hercules Tube used on 5.X (80/100), LS 5.X RT16, 7.X Part #: D3194T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERFORMIX PRO100/VCT (RG) & RT16 Systems FRU: Yes Status: Orderable Comments: Added per VCT RSPL, ms13452 041216 Comments: Added per VCT RSPL, ms13452 041216 FE ASSIST MSxxxx August 2005 D3194T = VCT / PRO 100 TUBE. VCT 32 or VCT 64 7.x systems may ONLY use D3194T tubes. 5.x HP 100 and HP80 Gdas systems may use either D3192T or D3194T tubes. '*** 2ND OPINION NOTES *** Perform Rotor Control Diagnostics--If tube rotor fails to reach RUN mode in three ACCEL steps look for: High Drive output currents Low Drive output voltages and Low Drive output frequencies. This indicates a load problem with tube. With rotor running turn off Gantry 120V power at PDU. Listen for excessive noise and short deceleration time. A good rotor will coast for several minutes without power. NOTE TO FES AND DCOS TEAM: IF SELLING TO AN END USER AND NOT INSTALLED BY A GE FE, AN END USER CERTIFICATION LETTER MUST BE SIGNED BY THE CUSTOMER. UPON RECEIPT OF SIGNED LETTER, ORDER CAN BE PLACED. **TO OBTAIN COPY OF CERT. LTR. CONTACT DCOS TEAM AT 800-558-2040 OPTION 2. **ANY QUESTIONS, CONTACT LYNN WESTBROOK OR ROD MCCRIMMON. ******* NOTE: D3194T tubes now manufactured, have a one inch longer high voltage cable. The longer cable is necessary for all Wide Bore Gantries. ( If a very old D3194T tube is installed on a Wide Bore Gantry, the high voltage cable may be too short, and a new D3194T tube must be ordered ).
Area
CT

Full cause & step-by-step resolution