GE Healthcare · CTLightSpeedVCTHiSpeed260134806260134825
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
The table is frozen, will not move THE TABLE IS FROZEN/WILL NOT MOVE
Error message
Error: 260134806 IMS tape switch OUT (front) isn’t present. See Long Description Thu Nov 10 08:51:41 2005 Error: 260134806 Host: tgp Process: tgp_subsys File: gtcb_imc_isrfunc.cxx Line: 172 Thu Nov 10 08:51:42 2005 Host : Table Sub-System Ermes # : 260134806 Exception Class : Secondary Severity : Pri/Soft File : gtcb_imc_isrfunc.cxx Line# : 172 Function : No System Function Reported Scan Type : None/Unknown Scan: 405/2/0 IMS tape switch OUT (front) isn't present. Position is 75 um. Error: 260134825 IMS cannot move because any of touch switches are already contacted or disconnected. See Long Description for complete error Fri Jan 26 16:53:26 2007 260134825 tgp tgp_subsys gtcb_imc_message.cxx 190 Fri Jan 26 16:53:26 2007 Host : Table Sub-System Ermes # : 260134825 Exception Class : Secondary Severity : Pri/Soft File : gtcb_imc_message.cxx Line# : 190 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 IMS cannot move because any of touch switches are already contacted or disconnected. Type of the touch switches will be shown above log message.
Applies to
- Models
- LightSpeed, VCT, HiSpeed
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required