GE Healthcare · CTLightSpeed260115217260115242
LightSpeed 5.X (60kW)
Symptom
Table moves up ok when empty, but will not go up with patient loaded on table. see long description Table moves up ok when empty, but will not go up at all with a patient loaded on the table. Even lighter patients are causing a problem. Often if the table is all the way down when this happens and if the patient is removed from he table, then the table is raised a foot or two and then the patient is put back on it will move up and down as normal, until it is lowered too low.
Error message
Error: 260115217 No response from serial device (Cradle or Elevation Drive) See LD for a sample of full error. Fri Oct 14 10:18:27 2005 Error: 260115217 Host: tgp Process: tgp_subsys File: pacsci_actions.c Line: 284 Fri Oct 14 10:18:28 2005 Host : Table Sub-System Ermes # : 260115217 Exception Class : Soft Severity : Pri/Soft File : pacsci_actions.c Line# : 284 Function : No System Function Reported Scan Type : None/Unknown Scan: 232/1/0 No response from serial device (Cradle drive) seq num 94 reply needed 0 command ff04 This same error could say "No response from serial device (Elevation Drive)" Error: 260115242 MTCB elevation invalid Pacsci drive model set See long description Sun Aug 1 00:34:35 2010 Error: 260115242 Host: tgp Process: tgp_subsys File: mtcb_emc_drv_req.c Line: 341 Sun Aug 1 00:34:35 2010 Host : Table Sub-System Ermes # : 260115242 Exception Class : Secondary Severity : Pri/Soft File : mtcb_emc_drv_req.c Line# : 341 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 . MTCB elevation invalid Pacsci drive model set. Invalid elevation current Model = 1
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2100671 CT TABLE GAS SPRING - Used on ALL HSA, CTi, LightSpeed 1.X through 5.X tables Part #: 2100671 Part Type: GP CONSUMABLES Part Weight: 1.40 LBR Repairable: No Returnable: No Hazardous Material: N Description: CT Table gas spring FRU: Yes Status: Orderable Comments : FLS - REPLACES 46-327064P1 & 46-296891P1 PER PCN 161843 7-20-93 MS4398. NOT ON SSS: SUSPA IS NOT SUPPLIER. TOOL FOR REPLACING GAS SPRING IS 2144261 ************************************************************PART HAS BEEN DE-LISTED AS A HAZARDOUS MATERIAL ITEM. PART IS NOT HAZARDOUS FOR ANY MODE OF TRANSPORTATION. HAZARDOUS PAPERWORK IS NOT NEEDED. 4/99 ************************************************************ ALSO USED ON QXI LIGHTSPEED ALSO USED ON LIGHTSPEED GELS - "NON FLAMMABLE GAS - HAZ IATA DESC. ""ARTICLES, PRESSURIZED, PNEUMATIC "" UN 3164 - CLASS 2.2",GAS SPRING HAZ #8 is the shock
- Area
- CT