GE Healthcare · CTLightSpeedVCT230011073403010440230019002
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Console will not boot. Getting input signal 1 no input displayed on both monitors for a short time after console power is turned on then the monitors go blank. Getting input signal 1 no input displayed on both monitors for a short time when cycling console power then the monitors go blank . Console will not boot. Getting input signal 1 no input displayed on both monitors for a short time after console power is turned on then the monitors go blank
Error message
Error: 230011073 Unix system error : 11 --- ( variations in text ) See Long Description for complete error. Variations in text of error Multiple examples slightly different. Fri Apr 21 07:30:27 2006 Error: 230011073 Host: oc01 Process: scanmgr File: sdio xfs api.c Line: 4074 Function: Data Acquisition : SBC Processing Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Error detected closing information file. Shutdown processing will continue. Info file: /raw data/info file Unix system error : 11 --- Resource temporarily unavailable. Mon Nov 6 07:53:41 2006 Error: 230011073 Host: gect1 Process: sfm_archive File: sdio_xfs_api.c Line: 4101 Function: System Control : Scan Database Manager Scan Type: Not scanning Scan: 0/0/0 Error detected closing information file. Shutdown processing will continue. Info file: /raw_data/info_file OS error : 4 --- Interrupted system cal Mon Nov 6 07:53:41 2006 Error: 230011073 Host: gect1 Process: sfm_archive File: sdio_xfs_api.c Line: 4101 Function: System Control : Scan Database Manager Scan Type: Not scanning Scan: 0/0/0 Error detected closing information file. Shutdown processing will continue. Info file: /raw_data/info_file OS error : 4 --- Interrup
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 10MW06.5 Titan for VCT (MUST HAVE SP1 or Higher) Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release) 10MW06.5 Titan for VCT Delivered via new install or FMI 25425 Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required