LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Cannot peform BOW scans after tube change
Error message
Error: 230017828 X-ray beam edge not detected on channel X row X (zero based). Check Z-alignment. If Z-alignment is within spec, check DAS/Detector for given channel and row. See long description Sat Apr 19 02:58:40 2008 Error: 230017828 Host: ctls Process: accs File: collSweepProcessing.c Line: 2365 ACCS ColimatorCal: Processing: large spot 32x1.25 X-ray beam edge not detected on channel 0 row 0 (zero based). Check Z-alignment. If Z-alignment is within spec, check DAS/Detector for given channel and row. Notes on this error. Channel number is 1 less than Detector Channel number. (ie Zero based numbering) So if the channel number is listed as 0 (zero) Detector Channel is 1 and it is on FRDM 1. If the channel number is 448 then that is the same as Detector channel number is 449 and it is on FRDM 29
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required