GE Healthcare · MRSigna222362122776622277672153735722776761525468
ICN disk error 2277662 in log Due To ICN Disk.
Symptom
ICN disk error 2277662 in log No issue seen by customer. 2277662 Disk error reported on ICN%s.
Error message
2223621 Internal Software Error. Can't callback on undefined NMRID:CM_ECHO_TPS. 2223621 Exception Class: Unknown Function: Software/Firmware: Host Communications Internal Software Error. Can't callback on undefined NMRID:CM_ECHO_TPS. 2277662 Disk error reported on ICN%s 2277662 ERROR: EM_DIAG_ICN_SMART_SUMMARY Disk error reported on ICN:%s Reported summary is as follows. Disk Device: %s Device String: %s Device Type: %s First Reported Date: %s Message: %s Extended Error: Run ICN Hard Disk Bandwidth test. If Bandwidth test fails: Stop scanning. Replace the ICN hard disk. Reconfigure ICNs. If Bandwidth test passes: Run ICN Hard Disk Integrity test If Integrity test passes: Continue scanning. Place order for new hard disk. Replace and reconfigure once new disk is obtained If Integrity test passes: Stop scanning. Replace hard disk immediately and reconfigure ICN. Possible cause(s): Img Compute Node, ICN Disk 2277672 TPS Reset ICN Boot Log Analysis detected an improper shutdown Mon Feb 23 06:44:04 2009 Error: 2277672 Host: EPMR02 Process: diagCoord File: icnBootLogCheck.pl Line: 358 Exception Class:Notification Function: Software/Firmware/Config:N/A TPS Reset (ICN Boot Log Analysis) d
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- SecondOpinion Image Compute Node 5127452 See comments in Resolution Concept for second opinion requirements before ordering this part.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.