GE Healthcare · CTDiscoveryVCT2601110275139591260111048
Gantry Control Panel Flashing "ERR".
Symptom
Gantry Control Panel Flashing "ERR". Gantry Control Panel Flashing "ERR"
Error message
Error: 260111027 Gantry Control Button is non-functional See long description for full error Fri Oct 19 09:48:15 2007 Error: 260111027 Host: tgp Process: tgp_subsys File: guif_can_mgr2.c Line: 5817 Fri Oct 19 09:48:15 2007 Host : Table Gantry Processor Ermes # : 260111027 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 5817 Function : OPERATOR INPUT/OUTPUT : Gantry Operator Interface Scan Type : None/Unknown Scan: 0/0/0 Gantry Control Alignment Light button is non-functional. Node Id: 4, Board Number: 5139591, Serial Number: 5184. This error number could be any of the buttons on the Control Panel. The error number is the same, but the verbage for each button is different. Error: 260111048 Gantry Control button hardline is active at gantry start-up. Mon Aug 9 15:09:39 2010 260111048 2 tgp tgp_subsys guif_can_mgr2.c 6215 Mon Aug 9 15:09:40 2010 Host : Table Gantry Processor Ermes # : 260111048 Exception Class : Secondary Severity : Pri/Soft File : guif_can_mgr2.c Line# : 6215 Function : OPERATOR INPUT/OUTPUT : Gantry Operator Interface Scan Type : None/Unknown Scan: 0/0/0 Gantry Control button hardline is active at gantry start-up. If nobody touched bu
Applies to
- Models
- Discovery, VCT
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required