GE Healthcare · CTLightSpeedVCT260111002

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Gantry Control Panel Flashing "ERR". Gantry Control Panel Flashing "ERR"

Error message

Error: 260111002 GUIF CAN bus error warning See the LD for the full error code Error: 260111002 GUIF CAN bus error warning Mon May 16 07:45:39 2005 Error: 260111002 Host: tgp Process: tgp subsys File: guif can mgr.c Line: 483 Mon May 16 07:45:39 2005 Host : Table Gantry Processor Ermes # : 260111002 Exception Class : Soft Severity : Sec/Soft File : guif can mgr.c Line# : 483 Function : OPERATOR INPUT/OUTPUT : Gantry UIF Communications Scan Type : None/Unknown Scan: 0/0/0 GUIF CAN bus error warning. 96 CAN bus errors have occured. GUIF CAN bus error status returned. Error status 0x3

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5139591 control assembly right side gantry ( replaces part# 2256728 and 2330703 ) ) – used on LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x (HD uses a different control panel) See Long Description. 5139591 control assembly right side gantry ( replaces part# 2256728 and 2330703 ) ) – used on H2 gantry,s (LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x ) Part #: 5139591 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: H POWER OPERATOR CONTROLS RIGHT SIDE FRU: Yes Status: Orderable OLD part info 2256728 control assembly right gantry Part #: 2256728 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: CONTROL ASM RIGHT H2 GANTRY FRU: Yes Status: Orderable Comments: If no stock is available, order 5139591 per ECR 2025944; 6/20/2006 MS11892 FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA Part #: 2330703 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: H POWER OPERATOR CONTROLS RIGHT SIDE FRU: Yes Status: Orderable Parts Offered as: Current: 2330703 Harvested: Not Available Exchange: Not Available Comments: If no stock is available, order 5139591 per ECR 2025944; 6/20/2006 MS11892. 212012201 02/09/2007 19:34 GMT
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.